For professionals

Partners

We work with laser cleaning across the Balearic Islands, for shipyards, marinas, heritage architecture studios and restorers. We didn't invent the method: in heritage conservation it has been the standard for decades. What we're doing is bringing it to a market — the Balearic one — where it's still the exception.

Working on your site

Equipment classification

The equipment is a Class 4 laser. That means a marked, restricted work zone, controlled access during treatment, and eye protection specific to the 1064 nm wavelength for anyone inside the area. We set these conditions before starting, not as we go.

Ignition risk

Ablation throws off hot particulate. On a site with solvents, resins or fibreglass, that's a real risk and we treat it as one: a defined work zone, flammable material cleared from the projection radius beforehand, and a fire extinguisher on hand throughout.

Fume extraction

Removing antifouling with a laser releases airborne particulate carrying the coating's own biocides — copper, zinc, and occasionally other metals in older paints. It's not just an air-quality question, it's occupational exposure, and we handle it with local extraction and filtration right at the work zone.

Power and space

The equipment runs off the site's standard mains supply — no generator or special installation. We confirm access and the working space needed when we schedule the visit.

Heritage and restoration

We work under a minimal-intervention principle: only what needs removing comes off, nothing more. Before treating a full surface we run one or more test patches, documented with photographs, to set power and pulse width for that specific substrate. If the project is under the direction of a conservator or heritage architect, we work to their specification — we don't replace it with our own judgement.

Technical specifications

The source is MOPA, which allows the pulse width to be adjusted: a gentle setting for teak or gilding, a stronger one for rust on iron. That's the feature that explains why the same unit doesn't damage such different substrates — not the power output itself.

Source and beam
Source Pulsed MOPA (JPT)
Wavelength 1064 nm
Average power up to 500 W
Pulse width 30–500 ns, adjustable
Repetition rate 1–4,000 kHz
Pulse energy up to 50 mJ
Power supply and head
Power supply 220 V
Cooling air-cooled
Optical fibre armoured, 10 m
Head weight ≤ 1.5 kg
Optics and software
Field lenses F160 · F210 · F254 · F420
Protective window replaceable
Software preset recipes and programs

Pulse energy and repetition rate are the extremes of the source's range, not a simultaneous setting: the 50 mJ figure is only reached at low frequencies (around 10 kHz), while at 4,000 kHz pulse energy drops to about 0.125 mJ.